Columbia-Spas Aeware Manual do Utilizador Página 51

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 50
50
in.xm
in.xm electrical specifications:
Input rating : 120/240 VAC (2-phase required, with or
without neutral) 48 A maximum, 60Hz.
specications
Output ratings:
Output Voltage Current Device
Out 1 240 V 20FLA Pump 1
Out 2 240 V 15 FLA Pump 2
Out 3 120/240V 15 FLA Pump 3 or large Blower
Out 4 120/240V 6 FLA Aux 1
Out 5 120/240V 6 FLA Blower
Out 6 120/240V 6 FLA Circulation Pump (CP)
Out 7 120/240V 6 FLA Ozone Generator
Out 8 120/240V 6 FLA Audio/Video device
L1 Light, 12VAC, 1 A
CO Communications port *
C1 Top side controller *
C2 Top side controller **
IO General purpose I/O port **
* C1 and CO: 125 mA max on 5 Volts.
** C2 and IO: 125 mA max on 5 Volts.
Important:
48 A absolute maximum, distributed on all outputs
25 A maximum total for all 120 VAC loads
20 A maximum total for OUT2 and OUT3 combined
11 A maximum total for OUT4 to OUT8 combined
Maximum loads are determined by fusing restrictions and
ambient temperature. In all output configurations, the total
current output must never exceed input ratings.
Important:
All low voltage acccessories use + 5Vdc and/or on + 12 Vdc.
All low voltage acccessories combined:
300 mA max, on + 12 Vdc.
Vista de página 50