50
in.xm
in.xm electrical specifications:
Input rating : 120/240 VAC (2-phase required, with or
without neutral) 48 A maximum, 60Hz.
specifications
Output ratings:
Output Voltage Current Device
Out 1 240 V 20FLA Pump 1
Out 2 240 V 15 FLA Pump 2
Out 3 120/240V 15 FLA Pump 3 or large Blower
Out 4 120/240V 6 FLA Aux 1
Out 5 120/240V 6 FLA Blower
Out 6 120/240V 6 FLA Circulation Pump (CP)
Out 7 120/240V 6 FLA Ozone Generator
Out 8 120/240V 6 FLA Audio/Video device
L1 Light, 12VAC, 1 A
CO Communications port *
C1 Top side controller *
C2 Top side controller **
IO General purpose I/O port **
* C1 and CO: 125 mA max on 5 Volts.
** C2 and IO: 125 mA max on 5 Volts.
Important:
• 48 A absolute maximum, distributed on all outputs
• 25 A maximum total for all 120 VAC loads
• 20 A maximum total for OUT2 and OUT3 combined
• 11 A maximum total for OUT4 to OUT8 combined
• Maximum loads are determined by fusing restrictions and
ambient temperature. In all output configurations, the total
current output must never exceed input ratings.
Important:
• All low voltage acccessories use + 5Vdc and/or on + 12 Vdc.
• All low voltage acccessories combined:
300 mA max, on + 12 Vdc.
Comentários a estes Manuais